000010080 001__ 10080 000010080 005__ 20240125143605.0 000010080 0247_ $$2DOI$$a10.6083/r781wg66p 000010080 037__ $$aIR 000010080 245__ $$aTraumatic hematoma volumes measurements with 3D-Slicer software may show less variation when compared to ABC/2 formula 000010080 260__ $$bOregon Health and Science University 000010080 269__ $$a2023 000010080 336__ $$aCapstone 000010080 502__ $$gMedicine (Undergraduate Medical Education) 000010080 502__ $$bM.D. 000010080 520__ $$aIn this retrospective analysis of CT scan images from a group of prospectively enrolled patients with progression of traumatic cerebral hematoma, we asked whether there is a difference in volumes measured between the conventional ABC/2 formula and a semi-automated computer software, 3D-Slicer. We found that the conventional ABC/1 formula demonstrated a high degree of variability with a clinically significant mean difference in hematoma volume between readers. Additionally, when hematoma volumes were large, there was more variability in the measurements suggesting 3D-Slicer measurements might be more consistent in larger hematomas. 000010080 540__ $$fCC BY 000010080 650__ $$aBrain Injuries, Traumatic$$011616 000010080 650__ $$aCerebral Hemorrhage, Traumatic$$032220 000010080 6531_ $$avolumetric 000010080 691__ $$aSchool of Medicine$$041369 000010080 7001_ $$aDegener-O'Brien, Kiera$$uOregon Health and Science University$$041354 000010080 7201_ $$aMunger, Daniel$$uOregon Health and Science University$$041354$$7Personal$$eCo-PI 000010080 7201_ $$aSiler, Dominic$$uOregon Health and Science University$$041354$$7Personal$$eCo-PI 000010080 7201_ $$aHinson, Holly$$uOregon Health and Science University$$041354$$7Personal$$eMentor 000010080 8564_ $$9294bd1f8-c498-40b4-b3a2-b2541292b243$$s762164$$uhttps://digitalcollections.ohsu.edu/record/10080/files/DegenerOBrien.Kiera.2023.pdf 000010080 905__ $$a/rest/prod/r7/81/wg/66/r781wg66p 000010080 909CO $$ooai:digitalcollections.ohsu.edu:10080$$pstudent-work 000010080 980__ $$aScholarly Project Capstones