TY - THES N2 - This work is concerned with the comparison of two different dynamic conformal arc therapy (DCAT) stereotactic radiosurgery (SRS) planning systems, namely Eclipse and BrainLab Elements. The creation of an SRS plan is an involved process with many parameters to be considered and the treatment efficacy is sensitive to the accuracy of its delivery. As a result, the process of effective plan creation with acceptable normal tissue and organ at risk (OAR) sparing can be time consuming. The Elements treatment planning system (TPS) offers a streamlined approach to creating cranial SRS plans. The intention of this study is to dosimetrically compare each system to understand any potential gains in utilizing the Elements TPS.? DO - 10.6083/8c97kr02z DO - DOI AB - This work is concerned with the comparison of two different dynamic conformal arc therapy (DCAT) stereotactic radiosurgery (SRS) planning systems, namely Eclipse and BrainLab Elements. The creation of an SRS plan is an involved process with many parameters to be considered and the treatment efficacy is sensitive to the accuracy of its delivery. As a result, the process of effective plan creation with acceptable normal tissue and organ at risk (OAR) sparing can be time consuming. The Elements treatment planning system (TPS) offers a streamlined approach to creating cranial SRS plans. The intention of this study is to dosimetrically compare each system to understand any potential gains in utilizing the Elements TPS.? T1 - Dosimetric comparison between two treatment planning systems for DCAT in single and multi-lesion patients DA - 2021 AU - Berzanske, John T., IV L1 - https://digitalcollections.ohsu.edu/record/9146/files/Berzanske.John.2021.pdf PB - Oregon Health and Science University PY - 2021 ID - 9146 L4 - https://digitalcollections.ohsu.edu/record/9146/files/Berzanske.John.2021.pdf KW - Radiometry KW - Radiotherapy KW - Radiosurgery KW - Radiotherapy Dosage KW - Elements KW - Treatment Outcome KW - cranium KW - stereotactic radiosurgery TI - Dosimetric comparison between two treatment planning systems for DCAT in single and multi-lesion patients Y1 - 2021 L2 - https://digitalcollections.ohsu.edu/record/9146/files/Berzanske.John.2021.pdf LK - https://digitalcollections.ohsu.edu/record/9146/files/Berzanske.John.2021.pdf UR - https://digitalcollections.ohsu.edu/record/9146/files/Berzanske.John.2021.pdf ER -